User`s manual
UC-7101/7110/7112 Software User’s Manual Configuring UC-7101/7110/7112
You will also need to restore factory defaults to load the new settings. To do this, either press the
RESET button for more than 5 seconds, or input the command “stdef” from the Telnet console.
Loading Factory Defaults
The easiest way to “Load Factory Defaults” is with the “Upgrade User directory” operation.
Refer to the previous section Upgrading the Root File Sysem & User Directory for an
introduction.
You may also press the RESET button for more than 5 seconds to load the factory default
configuration or input the command “stdef” from the Telnet console to restore the factory defaults.
Autostarting User Applications on Bootup
To autostart user applications on bootup, edit the /etc/rc file by adding your application program.
For example, you might add the following line to the file:
/ap-directory/ap-program &
Checking the Kernel and Root File System Versions
Use the following commands to check the version of the kernel and root file system:
Use the following command to check the kernel version:
/>kversion
Use the following command to check the root file system (firmware) version of the
UC-7101/7110/7112:
/>fsversion
Use the following command to check the user directory version of the UC-7101/7110/7112:
/>cat /etc/version
4-12