Installation guide

- 6 -
Panel/Wall Mounting
Mounting the TN-5308-LV/MV on the wall requires 3 screws. Please use
the 3 screws packed in the panel mounting kit.
STEP 1: Prepare the 3 screw holes on the wall according to the positions
of the 3 screw holes on the switch shown on the mounting dimension
diagram.
STEP 2: Use one screw to go through the top-middle screw hole on the
switch and screw it into the wall.
STEP 3: Screw in the remaining 2 screws through the bottom-left and
bottom-right holes on the switch to the wall.
NOTE
The screw lengths of TN
-5308-LV and TN-5308-
MV are different.
TN
-5308-LV uses M3 * 30 mm screws. TN-5308-
MV uses M3 * 40
mm screws. Please use the screws packed in the panel mounting
kit.
DIN-Rail Mounting (optional)
With the optional DIN-Rail mounting kit DK-TN-5308 (must be purchased
separately), you can mount the TN-5308-LV/MV on a 35mm DIN-Rail.
-Rail attachment plate onto the
STEP 2:
Position the TN-5308-LV/MV on
the DIN-Rail, tilting to hook clamps
over the top edge of the rail.
STEP 3:
Swing the switch down fully onto
the DIN-Rail until both clamps
completely latch.
To remove the Moxa ToughNet Switch from the DIN-Rail, simply reverse
Steps 2 and 3 above.