Specifications
Industrial Networking Solutions
3-59
info@moxa.com
www.moxa.com
3
Industrial Ethernet Switches >
EDS-305/308/309/316 Series
Technology
Standards:
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100Base FX
IEEE 802.3x for Flow Control
Processing Type: Store and Forward
Flow Control: IEEE 802.3x fl ow control, back pressure fl ow control
Interface
Fiber Ports: 100BaseFX ports (SC/ST connector)
RJ45 Ports: 10/100/1000BaseT(X) auto negotiation speed, F/H
duplex mode, and auto MDI/MDI-X connection
DIP Switches: Port break alarm mask
LED Indicators: PWR1, PWR2, FAULT, 10/100M (TP port), 100M
(fi ber port)
Alarm Contact: 1 relay output with current carrying capacity of 1 A @
24 VDC
Optical Fiber
Power Requirements
Input Voltage:
EDS-305/308: 24 VDC (12 to 48 VDC), redundant inputs
EDS-309/316: 24 VDC (12 to 45 VDC), redundant inputs
Input Current:
EDS-305: 0.13 A @ 24 V
EDS-305-M/S: 0.17 A @ 24 V
EDS-308: 0.13 A @ 24 V
EDS-308-M/S: 0.21 A @ 24 V
EDS-308-MM/SS: 0.26 A @ 24 V
EDS-309-3M: 0.31 A @ 24 V
EDS-316: 0.27 A @ 24 V
EDS-316-M/S/MM/SS/MS: 0.44 A @ 24 V
Overload Current Protection:
EDS-305, EDS-305-M, EDS-305-S, EDS-308: 1.1 A
EDS-308-M/S/MM/SS, EDS-309 series, EDS-316 series: 1.6 A
Connection: 1 removable 6-pin terminal blocks
Reverse Polarity Protection: Present
Physical Characteristics
Housing: Metal, IP30 protection
Dimensions:
EDS-305/308/309 Series:
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
EDS-316 Series:
80.5 x 135 x 105 mm (3.16 x 5.31 x 4.13 in)
Weight:
EDS-305/308/309 Series: 630 g
EDS-316 Series: 1140 g
Installation: DIN-Rail mounting, wall mounting (with optional kit)
5, 8, 9, and 16-port unmanaged Ethernet switches
EDS-305/308/309/316 Series
Introduction
The EDS-305/308/309/316 are 5, 8, 9, and 16-port Ethernet switches
that provide an economical solution for your industrial Ethernet
connections. The built-in relay warning function alerts network
engineers when power failures or port breaks occur, and the switches
are designed for harsh industrial environments, such as in hazardous
locations (Class I, Div. 2/ATEX). The switches comply with FCC,
Redundant dual 24 VDC power inputs
›
Relay output warning for power failure and port break alarm ›
Broadcast storm protection ›
Transparent transmission of VLAN tagged packets ›
-40 to 75 › °C operating temperature range (T models)
Specifi cations
100BaseFX
Multi-mode Single-mode Single-mode, 80 km
Wavelength 1300 nm 1310 nm 1550 nm
Max. TX -10 dBm 0 dBm 0 dBm
Min. TX -20 dBm -5 dBm -5 dBm
RX Sensitivity -32 dBm -34 dBm -34 dBm
Link Budget 12 dB 29 dB 29 dB
Typical
Distance
5 km, 2 km (EDS-316-T)
a
40 km
c
80 km
d
4 km, 2 km (EDS-316-T)
b
Saturation -6 dBm -3 dBm -3 dBm
a. 50/125 µm, 800 MHz*km fi ber optic cable
b. 62.5/125 µm, 500 MHz*km fi ber optic cable
c. 9/125 µm single-mode fi ber optic cable
d. 9/125 µm single-mode fi ber optic cable (80 km)
The certifi cation logos shown here apply to some or all of the products in this
section. For details, see “Regulatory Approvals” under “Specifi cations” below.
TÜV, UL, and CE standards, and come in two model types. Standard
operating temperature range models (0 to 60°C) and wide operating
temperature range models (-40 to 75°C). Both models undergo a
100% burn-in test to ensure that they fulfill the special needs of
industrial automation control applications. The EDS-305/308/309/316
switches can be installed easily on a DIN-Rail or in a distribution box.