Test Report ------------------------------------------------------------------------------6/30
Report No.: M47ET060805 (ETSI EN 300 328)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
1.5 Verify the Frequency and Channel
CH 1 2 3 4 5 6 7 8 9 10
0 2412 2417 2422 2427 2432 2437 2442 2447 2452 2457
1 2462 2467 2472 --- --- --- --- --- --- ---
Note:
(1) This is for sure that all frequencies are in 2.4GHz – 2.4835 GHz.
(2) After test, the EUT (IEEE 802.11b/g) operating frequencies are in 2.412GHz to 2.472GHz. So
all the item as followed in testing report are need to test these three frequencies:
channel 1, channel 7, and channel 13.
(3) E.T.S.I (2400MHz ~ 2483.5MHz),
FRANCE outdoor use limited to 10mW e.i.r.p. within the band (2454MHz ~ 2483.5MHz)
1.6 Test Procedure
All measurements performed in this report were performed mainly according to the techniques
described in ETSI EN 300328 (November, 2004) and the pre-setup was written on 1.4
test method,
the detail setup was written on each test item.
1.7 Location of the Test Site
The radiated emissions measurements required by the rules were performed on the
three-meter, Anechoic Chamber (Registration Number: 93906) maintained by Training Research
Co., Ltd. 1F., No. 255 Nanyang Street, Shijr, Taipei Hsien 221, Taiwan, R.O.C. Complete
description and measurement data have been placed on file with the commission. The conducted
power line emissions tests and other test items were performed in a anechoic chamber also located at