User manual

Test Report ------------------------------------------------------------------------------- 46/48
Report No.: M47ET060805 (ETSI EN 301 489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
List of test Instrument
Calibration Date
Instrument Name Model Brand Serial No. Next time
EMI Receiver 8546A HP 3520A00242 09/06/07
RF Filter Section 85460A HP 3448A00217 09/06/07
Small Biconical
Antenna
UBAA9114 &
BBVU9135
SCHWARZECK
127 12/07/07
Pre-amplifier PA1F TRC 1FAC 05/20/07
Auto Switch Box
(>30MHz)
ASB-01 TRC 9904-01 05/20/07
Coaxial Cable
(Double shielded,
15 meter)
A30A30-0058-50FS-15M JYEBAO SMA-08 05/20/07
Coaxial Cable
(1.1 meter)
A30A30-0058-50FS-1M JYEBAO SMA-02 05/20/07
Receiver SCR3102 SCHAFFNER 012 05/20/07
Control Box TWR95-4 TRC C9001-2 11/28/07
Antenna VULB 9160
SCHWARZECK
3063 05/31/07
Pre-amplifier TRC-CB-2 TRC CB-002 N/A
Coaxial cable
(20 meter)
RG-214/U JYEBAO Cl-002 05/31/07
Coaxial Cable
(50 cm)
BNC31VB-0316 JYEBAO SMA-02 05/28/07
Coaxial Cable
(1.1 meter)
BNC31VB-0318 JYEBAO SMA-02 05/28/07
Coaxial Cable
(1.1 meter)
BNC31VB-0316 JYEBAO SMA-02 05/28/07
Coaxial Cable
(1.1 meter)
BNC31VB-0316 JYEBAO SMA-02 05/28/07
The level of confidence of 95% , the uncertainty of measurement of radiated emission is +2.85dB / -2.77dB .