Test Report ------------------------------------------------------------------------------- 44/48
Report No.: M47ET060805 (ETSI EN 301 489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test Result of Conducted Emissions for Mains Power
Testing room : Temperature : 25 ° C Humidity : 73 % RH
Line 1
READING AMPLITUDE LIMIT
Frequency
(kHz)
Peak
(dB
µ
V)
Quasi-Peak
(dB
µ
V)
Average
(dB
µ
V)
Quasi-Peak
(dB
µ
V)
Average
(dB
µ
V)
Margin
(dB)
172.000 58.19 --- --- 79.00 66.00 -7.81
279.000 55.07 --- --- 79.00 66.00 -10.93
472.000 51.92 --- --- 79.00 66.00 -14.08
724.000 45.30 --- --- 73.00 60.00 -14.70
1186.000 38.38 --- --- 73.00 60.00 -21.62
7392.000 41.30 --- --- 73.00 60.00 -18.70
10600.000 40.25 --- --- 73.00 60.00 -19.75
17700.000 36.24 --- --- 73.00 60.00 -23.76
25300.000 20.66 --- --- 73.00 60.00 -39.34
Line 2
READING AMPLITUDE LIMIT
Frequency
(kHz)
Peak
(dB
µ
V)
Quasi-Peak
(dB
µ
V)
Average
(dB
µ
V)
Quasi-Peak
(dB
µ
V)
Average
(dB
µ
V)
Margin
(dB)
150.000 57.58 --- --- 79.00 66.00 -8.42
198.000 55.41 --- --- 79.00 66.00 -10.59
331.000 51.68 --- --- 79.00 66.00 -14.32
605.000 43.65 --- --- 73.00 60.00 -16.35
1567.000 26.94 --- --- 73.00 60.00 -33.06
4896.000 25.57 --- --- 73.00 60.00 -34.43
7392.000 41.53 --- --- 73.00 60.00 -18.47
10760.000 40.77 --- --- 73.00 60.00 -19.23
17700.000 36.05 --- --- 73.00 60.00 -23.95
25300.000 24.69 --- --- 73.00 60.00 -35.31
Note:
1. The reading amplitudes are all under limit.
2. Testing result = Amplitude reading + Correction factor (Insertion loss of LISN, Cable loss,
Attenuator, Amplifier and so on)