User manual
Test Report ------------------------------------------------------------------------------- 34/48
Report No.: M47ET060805 (ETSI EN 301 489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test Frequency: 0.15 ~ 80MHz
Modulation: FM %
80% AM Modulation with 1kHz
80% AM Modulation with 400Hz when signal is modulated at 1kHz
900 MHz±5 MHz with PM 200 Hz and 50% duty cycle
Step size: Performed over the frequency range 150kHz to 80MHz with the
exception of an exclusion band for transmitters, and for receivers and
duplex transceivers
For receivers and transmitters the stepped frequency increments shall
be 1% frequency increment of the momentary frequency in the
frequency range 150kHz to 80MHz, unless specified otherwise in the
part of EN 301 489 dealing with the particular type of radio equipment
Field strength: 1Vrms
3Vrms
10Vrms
Connected lines: Power line shielded
Power line non-shielded
Signal & Control line non-shielded
Signal & Control line shielded
Test mode: Ref. Test method of Chapter 1