Test Report ------------------------------------------------------------------------------- 33/48
Report No.: M47ET060805 (ETSI EN 301 489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 8 Continuous Wave Voltage Immunity Test
CS Test information:
Test setup: According to EN 61000-4-6
Immunity test to RF conducted disturbances:
Test levels: (Apply Level 2)
Frequency range 150kHz to 80MHz
Voltage level (e.m.f.)
Level
Uo [dB(µv)] Uo [V]
1 120 1
2 130 3
3 140 10
X Special
NOTE: the “X” is an open test level.
CDN
Auxiliary
equipment 1
Equipment
under test
CDN
Auxiliary
equipment 1
T
Ground reference plane
0.1 m
support
RF — generator
T2
Test generator
T: Termination 50ohm
T2: Power attenuator
(6dB)
CDN: Coupling and
decoupling network