User manual

Test Report ------------------------------------------------------------------------------- 27/48
Report No.: M47ET060805 (ETSI EN 301 489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Test levels: (Apply Level 2)
Open-circuit output test voltage (±10%) and repetition rate of the impulses (±20%)
On power supply port, PE On input/output signal, data and
control ports
Level
Voltage peak
kV
Repetition rate
kHz
Voltage peak
kV
Repetition rate
kHz
1 0.5 5 0.25 5
2 1 5 0.5 5
3 2 5 1 5
4 4 2.5 2 5
X Special Special Special Special
NOTE: the “X” is an open level. The level has to be specified in the dedicated equipment specification
Test setup: According to EN 61000-4-4
Test Voltage: DC Power line 0.5 KV, 5 KH
AC Power line 1 KV, 5 KHz
Signal & Control line 0.5 KV, 5 KHz;
1 KV, 5 KHz
Polarity: Positive
Negative
Test Duration: 1 minute
3 minutes
Connected lines: Power line shielded
Power line non-shielded
Signal & Control line non-shielded (RJ45)
Signal & Control line shielded