Test Report ------------------------------------------------------------------------------14/25
Report No.: M47ET060805 (ETSI EN 301 893)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
3.3 Power density
(1) Limit: ETSI EN 301 893 clause 4.3.2.1
Frequency range Mean EIRP density limit
5150 MHz to 5350 MHz 10 dBm
5470 MHz to 5725 MHz 17 dBm
Note: For devices without TPC, the limits shall be reduced by 3 dB, except when
operating in the band 5150MHz to 5250MHz.
(2) Test Condition:
Please refer to item 5.3.3.1 of the standard.
(3) Test Procedures
Please refer to item 5.3.3.2.1.3 and 5.3.3.2.2 of the standard.
(4)Deviation form test standard
No deviation.
Test Result:
Channel
Frequency
(MHz)
Reading
valuer
(dBm)
CF
(dB)
Ant.
Gain(dB)
Duty
cycle(dB)
Actually
Value
(dBm)
Limit
(dBm)
Margin
(dB)
CH 01 5180 -2.85 10.3 2.00 0 9.45 10.00 -0.55
CH 04 5140 -3.41 10.3 2.00 0 8.89 10.00 -1.11
Uncertainty
± 1.50dB
Note:
Duty cycle (X): 100%.
Power density (eirp)= Reading value. + Cable Loss + Antenna Gain (2.00dBi) +10 log (1/X),
= 9.45 dBm +10 log (1/X)
= 9.45 dBm + 0 dB
= 9.45 dBm