Test Report ------------------------------------------------------------------------------13/25
Report No.: M47ET060805 (ETSI EN 301 893)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
3.2 RF output power at the lowest power level of the TPC range
(1) Limit: ETSI EN 301 893 clause 4.3.2.2
u
ency range Mean EIRP limit
5150 MHz to 5350 MHz 17 dBm
5470 MHz to 5725 MHz 24 dBm
Note:
a. For devices using TPC, the RF output power during a transmission burst when
configured to operate at the lowest stated power level of TPC range shall not exceed the
levels given table.
b. The limits do not apply for devices without TPC or when operating in the band 5 150
MHz to 5250 MHz..
(2) Test Condition:
Please refer to item 5.3.3.1 of the standard.
(3) Test Procedures
Please refer to item 5.3.3.2.1.2 of the standard.
(4)Deviation form test standard
No deviation.
Test Result:
Not applied. It is operating in the band 5 150 MHz to 5250 MHz.