User manual

Test Report ------------------------------------------------------------------------------7/25
Report No.: M47ET060805 (ETSI EN 301 893)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
1.6 Verify the Frequency and Channel
CH 1 2 3 4
frequency
5180 5200 5220 5240
Note:
(1) This is for sure that all frequencies are in 5.150GHz ~ 5.250GHz.
(2) After test, the EUT (IEEE 802.11a) operating frequencies are in 5.180GHz ~ 5.240GHz. So all
the item as followed in testing report are need to test these three frequencies:
channel lowest and channel highest except carrier frequencies apply to each channel.
(3) Restricted to indoor use.
1.7 Test Procedure
All measurements performed in this report were performed mainly according to the techniques
described in ETSI EN 301893 (August, 2005) and the pre-setup was written on 5
test method, the
detail setup was written on each test item.
1.8 Location of the Test Site
The radiated emissions measurements required by the rules were performed on the
three-meter, Anechoic Chamber (Registration Number: 93906) maintained by Training Research
Co., Ltd. 1F., No. 255 Nanyang Street, Shijr, Taipei Hsien 221, Taiwan, R.O.C. Complete
description and measurement data have been placed on file with the commission. The conducted
power line emissions tests and other test items were performed in a anechoic chamber also located at
Training Research Co., Ltd.
No. 255 Nanyang Street, Shijr, Taipei Hsien 221, Taiwan, R.O.C. Training Research Co., Ltd.
is listed by the FCC as a facility available to do measurement work for others on a contract basis.