User`s manual

ThinkCore DA-660 WinCE User’s Manual Getting Started
2-5
\> time
The current time is: 5:27:17 PM
Enter the new time (hh:mm:ss): 16:02:00
\> time /T
4:02:04 PM
Adjusting RTC Time: Use the command hwclock -w to convert the system time to the RTC time.
\> hwclock -w
Use the command hwclock –w YYYY-MM-DD hh:mm:ss to manually update the RTC time.
\> hwclock –w 2005-12-23 15:00:00
Use the command hwclock to query the updated RTC time.
\> hwclock
2005-12-23 15:00:00
Starting and Stopping Services
After booting up, the DA-660 computer runs several services continuously to serve requests from
users or other programs. Notable services include telnet (“TEL0:”), console (“CON0:”), world
wide web HTTP (“HTP0:”), and file transfer FTP (“FTP0:”) etc. You seldom need to care about
these services. However, you still can start up or stop a service with its associated name by using
the command “services”. For example,
Start the FTP service by
\> services start FTP0:
Stop the FTP service by
\> services stop FTP0:
Troubleshooting Network Connectivity
The ipconfig tool prints the TCP/IP-related configuration data of a host including the IP addresses,
gateway and DNS servers.
\> ipconfig /all
Windows IP configuration
Ethernet adapter Local Area Connection:
IP Address: 192.168.4.127
Subnet Mask: 255.255.255.0
Adapter Name: IXP425ETHNPE2
Description: IXP425ETHNPE2
Adapter Index: 2
Address: 80 86 33 33 34 12
DHCP Enabled: NO
Ethernet adapter Local Area Connection:
IP Address: 192.168.14.202
Subnet Mask: 255.255.248.0
Default Gateway: 192.168.15.254
Adapter Name: IXP425ETHNPE1
Description: IXP425ETHNPE1