User`s manual
Table Of Contents
- 1. Introduction
- 2. Getting Started
- 3. Featured Functions
- Configuring Basic Settings
- Using Port Trunking
- Configuring SNMP
- Using Communication Redundancy
- Using Traffic Prioritization
- Using Virtual LAN
- Using Multicast Filtering
- Using Bandwidth Management
- Using Port Access Control
- Using IP Filter
- Using Auto Warning
- Using Line-Swap-Fast-Recovery
- Using Set Device IP
- Using Diagnosis
- LLDP
- Using Monitor
- Using the MAC Address Table
- Using System Log
- Using HTTPS/SSL
- A. MIB Groups
- B. Specifications
- C. Modbus/TCP Map

PT-7728 User’s Manual Featured Functions
3-60
Re-Auth
Setting Description Factory Default
Enable/Disable Select to require re-authentication of the client after a
preset time period of no activity has elapsed.
Disable
Re-Auth Period
Setting Description Factory Default
Numerical
(60 to 65535 sec.)
Specify how frequently the end stations need to reenter
usernames and passwords in order to stay connected.
3600
802.1X
Setting Description Factory Default
Enable/Disable Click the checkbox under the 802.1X column to enable
IEEE 802.1X for one or more ports. All end stations
must enter usernames and passwords before access to
these ports is allowed.
Disable
802.1X Re-Authentication
The PT-7728 can force connected devices to be re-authorized manually.
802.1X Re-Authentication
Setting Description Factory Default
Enable/Disable This enables or disables 802.1X Re-Authentication Disable
Local User Database Setup
When setting the Local User Database as the authentication database, set the database first.