PT-7324 Series User’s Manual Featured Functions
Description
Setting Description Factory Default
Max. 63
Characters
Specify an alias for each port, and assist the
administrator in remembering important
information about the port.
E.g., PLC 1
None
Speed
Setting Description Factory Default
Auto
Allows the port to use the IEEE 802.3u
protocol to negotiate with connected devices.
The port and connected devices will determine
the best speed and duplex for that connection.
100M-Full
100M-Half
10M-Full
10M-Half
Choose one of these fixed speed options if the
Ethernet device at the other end has trouble
auto-negotiating for line speed.
Auto
FDX Flow Control
This setting enables or disables the flow control capability of this port when the port transmission
speed setting is on auto mode. The final result will be determined by the auto process between the
PT-7324 and the connected device.
Setting Description Factory Default
Enable
Enables the flow control capability of this port
when in auto-nego mode.
Disable
Disables the flow control capability of this
port when in auto-nego mode.
Disable
Port Type
Setting Description Factory Default
Auto
Allows the port to auto detect the port type of
the Ethernet device at the other end and
change the port type accordingly.
Auto
Network
The Network configuration allows users to modify the usual TCP/IP network parameters. An
explanation of each configuration item follows.
3-3