User`s manual
CN2510 User’s Manual Setting Up Reverse Terminal
7-5
Setting Value Notes Necessity
TCP port number Each of CN2510’s serial ports is mapped to
a TCP port. To avoid conflicts with the TCP
port numbers for CN251’s other serial ports,
use the default values: 4001 for port 1, 4002
for port 2, etc.
Optional
Source IP
address
IP address for
the port
Specify an IP address for this port for
application purposes. If left blank, CN2510
will use its own IP address, in which case
you will need to specify different TCP port
numbers for different serial ports.
Optional
Destination IP
addr
IP address Assign a host IP address on the LAN for
exclusive port access. If left blank, all hosts
on the network will have access to this port.
Optional
Map Keys
<CR-LF> to
CR/LF/CR-LF When you enter the string <CR-LF>,
CN2510 will determine whether to send
<CR>, <LF>, or <CR-LF>.
Optional
Inactivity time 0-99 minutes Idle time before the port is disconnected
automatically. If set to 0 minutes, the port
will not disconnect.
Optional
Authentication
type
None/local
/server
None: Authentication is not required.
local: Check the ID stored in the
User_table (defined under the SERVER
MENU).
Server: Check the ID with the external
RADIUS server. Refer to Appendix C for
RADIUS installation information.
Optional
TCP alive check
time
0-99 minutes The time period CN2510 waits before
checking if the TCP connection is alive or
not. If no response is received, CN2510 will
reset the port and terminate the connection.
Optional
3. Press Esc to return to PORT MENU.
Configuring the Serial Ports
Open Port Menu Æ Line to configure serial port settings.
1. From the MAIN MENU, select Port, and then press Enter.
CN2510-8 CN2510-8_5631 V2.0 MAIN MENU
------------------------------------------------------------------------------
Server [Port] seTting sAve Utility Restart Exit
Examine/modify async server ports configuration
Enter: select ESC: previous menu