Setup guide

GRAVIMETRIC GATEWAY AND ETHERNET COMMUNICATIONS
4
them to communicate with each other. For example if the G2 Server has an I.P.
address of 192.168.1.100, then the G2 Client PCs and Ethernet to serial converters
must be assigned I.P. address ranging from 192.168.1.1 to 192.168.1.254 without
duplications. For TCP/IP configuration information beyond what is provided in this
document, contact a network administrator.
G2 Software Configuration –
When a blender is configured to use Ethernet,
(whether cabled or wireless) it is added to the G2 software in the Blender Edit screen.
The blender is added as a “TCP/IP Access” type blender. The information that allows
the G2 software to access the blender over Ethernet are: The Blender ID, the I.P.
address of the controller’s Ethernet device (labeled “WSB I.P.”) and the “Port” that the
Ethernet device is listening on. This information is the same whether wired or
wireless.