Setup guide
GRAVIMETRIC GATEWAY AND ETHERNET COMMUNICATIONS
30
5. Press 2 then enter, you will see:
Networking:
IP
1. IP Address(10.0.50.100)
2. Gateway(10.0.0.254)
3. Subnet Mask(255.255.0.0)
SNMP
4. SNMP(Enable)
5. SysName(name)
6. SysLocation(locaion)
7. SysContact(contact)
Input choice and enter(1~7):
6. Select 1, enter the IP Address of your GW21W-MAXI
7. Select 2, enter the Gateway of your network
8. Select 3, enter the Subnet Mask for your network
9. Press Esc to return to the previous menu
10. Press 4 (Com#), you will see:
COM1:
1. Link Mode(TCP Server/Virtual_Com Disabled/Filter
disabled/4660 )
2. COM Port(/CONSOLE/9600,None,8,1/None)
3. Keep Serial Buffer's Data While Connecting(Enable)
4. Packet Delimiter(2 ms)
Input choice and enter(1~4):
11. Press 2, COM Port, you will see:
COM Port: CONSOLE
1. Alias name():
2. Baud rate(9600):
3. Parity(None):
4. Data bit(8):
5. Stop bit(1):
6. Flow control(None):
Input choice and enter(1~6):