User`s manual
NPort S8000 Series Switch Featured Functions
6-2
Ethernet Settings
Port Settings
Enable
Setting Description Factory Default
Checked Allows data transmission through the port. Enabled
Unchecked Immediately shuts off port access.
ATTENTION
If a connected device or sub
-
network is wreaking havoc on the rest of the network, the Disable option under
Advanced Setting
s/Port gives the administrator a quick way to shut off access through this port immediately.
Description
Setting Description Factory Default
Media type Displays the media type for each module’s port N/A
Name
Setting Description Factory Default
Max. 63 Characters Specify an alias for each port, and assist the administrator in
remembering important information about the port.
E.g., PLC 1
None
Speed (Copper Port Only )
Setting Description Factory Default
Auto Allows the port to use the IEEE 802.3u protocol to negotiate
with connected devices. The port and connected devices will
determine the best speed for that connection.
Auto
100M-Full Choose one of these fixed speed options if the opposing
Ethernet device has trouble auto-negotiating line speed.
100M-Half
10M-Full
10M-Half
FDX Flow Ctrl.
This setting enables or disables the flow control capability of this port when the “port transmission speed”
setting is in “auto” mode. The final result will be determined by the “auto” process between the NPort S8000
and connected devices.
Setting
Description
Factory Default
Enable Enables flow control for this port when in auto-negotiate mode.
Disable