User`s manual
NPort S8000 Series Basic Settings and Device Server Configuration
5-24
The UDP port that the NPort listens to, and that other devices must use to contact the NPort. To avoid conflicts
with well known UDP ports, the default is set to 4001.
Parameter Copy
Apply the above setting to other serial ports, you may use the checkboxes at the bottom of the window to apply
the settings to one or more ports.
Disabled Mode
When Operation mode is set to Disabled, that particular port will be disabled. Check the “Apply the above
settings to all serial ports” to apply this setting to the other port.
Apply the above setting to other serial ports, you may use the checkboxes at the bottom of the window to apply
the settings to one or more ports.
Serial Parameters
Port alias
Setting Factory Default Necessity
1 to 16 characters
(E.g., PLC-No.1)
None Optional
Port Alias is specially designed to allow easy identification of the serial devices which are connected to the
NPort’s serial port.
Baud rate
Setting
Factory Default
Necessity
50 bps to 921600 bps 115200 bps Required