User`s manual

NPort S8000 Series Switch Featured Functions
6-62
NOTE
DIP switch 4 must be set to the ON position to enable DIP switches 1, 2, and 3. If DIP switch 4 is set to the
OFF
position, then DIP switches 1, 2, and 3 will all be disabled.
Turbo RingDIP Switch Settings
DIP 1 DIP 2 DIP 3 DIP 4
Reserved for future use. ON: Enables this NPort
S8000 as the Ring Master.
ON: Enables the default
Ring Couplingports.
ON: Activates DIP
switches 1, 2, 3 to
configureTurbo Ring
settings.
OFF: This NPort S8000 will
not be the Ring Master.
OFF
: Do not use this NPort
S8000 as the ring coupler.
OFF: DIP switches 1, 2, 3
will be disabled.
Turbo Ring V2 DIP Switch Settings
DIP 1 DIP 2 DIP 3 DIP 4
ON: Enables the default
Ring Coupling (backup)
port.
ON: Enables this NPort
S8000 as the Ring Master.
ON: Enables the default
Ring Couplingport.
ON: Activates DIP
switches 1, 2, 3 to
configureTurbo Ring V2
settings.
OFF: Enables the default
Ring Coupling (primary)
port.
OFF: This NPort S8000 will
not be the Ring Master.
OFF:
Do not use this NPort
S8000 as a ring coupler.
OFF: DIP switches 1, 2, 3
will be disabled.
NOTE
The DIP 1 setting will only be active if DIP 3 is in the ON position. If you set DIP 3 to OFF, then the default Ring
Coupling port will NOT be enabled, even
if DIP 1 is ON.
NOTE
The Turbo Ring Ports and Coupling Ports will be added automatically to all VLANs if you set DIP Switch 4 to the
ONposition.
NOTE
If you do not enable any of the NPort S8000 switches to be the Ring Master, the Turbo Ring protoc
ol will
automatically choose the NPort S8000 with the smallest MAC address range to be the Ring Master. If you
accidentally enable more than one NPort S8000 to be the Ring Master, these NPort S8000 switches will
auto
-negotiate to determine which one will be the Ring Master.
NOTE
If you use the browser interface to enable the DIP switches (by un
-checking the
Disable the Turbo Ring DIP
switch
checkbox), and then flip DIP switch 4 from ON to OFF, the Ring Ports and Coupling Ports that were
added to all VL
ANs will be restored to their previous software settings. (For details, please refer to the
Using
Virtual LANs
section of this manual).
System Monitoring
Serial Status
Serial to Network Connection
Go to Serial to Network Connections under Serial Status to view the operation mode and status of each
connection, for each serial port. All monitor functions will refresh automatically every 5 seconds.