User`s manual
NPort S8000 Series Switch Featured Functions
6-60
TFTP Server IP/Name
Setting Description Factory Default
IP Address of TFTP
Server
The IP or name of the remote TFTP server. Must be set up
before downloading or uploading files.
None
Configuration Files Path and Name
Setting Description Factory Default
Max. 40 Characters The path and file name of the NPort S8000’s configuration file in
the TFTP server.
None
Firmware Files Path and Name
Setting Description Factory Default
Max. 40 Characters The path and file name of the NPort S8000’s firmware file. None
Log Files Path and Name
Setting Description Factory Default
Max. 40 Characters The path and file name of the NPort S8000’s log file None
After setting up the desired path and file name, click Activate to save the setting, and then click Download to
download the prepared file from the remote TFTP server, or click Upload to upload the desired file to the
remote TFTP server.
Dip Switch Settings
Turbo Ring DIP Switches
The Turbo Ring DIP Switch page allows users to disable the four DIP switches located on the NPort S8000’s
outer casing. When enabled, the DIP switches can be used to configure basic settings for either the “Turbo Ring”
protocol or “Turbo Ring V2” protocol. A complete description of the settings is given below.
NOTE
The proprietary
“Turbo Ring” protocol (recovery time < 300 ms) was developed by Moxa in 2003 to provide
better network reliability and faster recovery time for redundant ring topologies. The
“Turbo Ring V2”
protocol
(recovery time < 20 ms), which was released in 2007, supports additional redundant ring architectures.
In this manual, we use the terminology
“Turbo Ring” ring and “Turbo Ring V2” ring to differentiate between
rings configured for on
e or the other of these protocols.
For a detailed description of
“Turbo Ring” and “Turbo Ring V2,” please refer to the Using Communication
Redundancy section later in this chapter.