User`s manual

NPort S8000 Series Switch Featured Functions
6-52
SNMP Trap
System Events Warning e-mail is sent when…
System Cold Start Power is cut off and then reconnected.
System Warm Start The NPort S8000 is rebooted, such as when network parameters
are changed (IP address, subnet mask, etc.).
Power Transition (OnOff)
The NPort S8000 is powered down.
Power Transition (OffOn)
The NPort S8000 is powered up.
DI1 (OnOff)
Digital Input 1 is triggered by on to off transition
DI1 (OffOn)
Digital Input 1 is triggered by off to on transition
DI2 (OnOff)
Digital Input 2 is triggered by on to off transition
DI2 (OffOn)
Digital Input 2 is triggered by off to on transition
Configuration Change Activated A configuration item has been changed.
Authentication Failure An incorrect password is entered.
Comm. Redundancy Topology Changed Spanning Tree Protocol switches have changed their position
(applies only to the root of the tree).
The Master of the Turbo Ring has changed or the backup path is
activated.
Serial Port Events
Warning e-mail is sent when…
DCD changed A change in the DCD (Data Carrier Detect) signal indicates that the modem
connection status has changed. For example, if the DCD signal changes to low, it
indicates that the connection line is down. When the DCD signal changes to low, the
NPort S8000 will automatically send a warning to the administrator as configured on
the Serial Event Settings page.
DSR changed A change in the DSR (Data Set Ready) signal indicates that the data communication
equipment is powered off. For example, if the DSR signal changes to low, it indicates
that the data communication equipment is powered down. When the DSR signal
changes to low, the NPort S8000 will automatically send a warning to the
administrator as configured on the Serial Event Settings page.