User`s manual
NPort S8000 Series Switch Featured Functions
6-50
Read/write Privacy: Use this field to define the encryption key for the specified level of access.
Read only: Read only authentication mode allows you to configure the authentication mode for read/write
access. For each level of access, you may configure the following:
Read/only User name: Use this optional field to identify the user name for the specified level of access.
Read/only Authentication mode (default=No-Auth): Use this field to select MD5 or SHA as the method of
password encryption for the specified level of access, or to disable authentication.
Read/only Password: Use this field to set the password for the specified level of access.
Read/only Privacy mode (default=Disable): Use this field to enable and disable DES data encryption for
the specified level of access.
Read/only Privacy: Use this field to define the encryption key for the specified level of access.
1st Trap Server IP/Name: Enter the IP address or the name of the 1
st Trap Server used by your network.
1st Trap Community: Use a community string match for authentication (maximum of 30 characters).
2nd Trap Server IP/Name: Enter the IP address or the name of the 2
nd Trap Server used by your network.
2nd Trap Community: Use a community string match for authentication (maximum of 30 characters).
Retries (Inform mode select): Enter the Inform Retry number Enter the numbers of retries before
Time out (Inform mode select): Enter Inform Timeout window
E-mail Event Settings
Event Types can be divided into three basic groups: System Events, Serial Port Events and Ethernet Port
Events.
System Events Warning e-mail is sent when…
System Cold Start Power is cut off and then reconnected.
System Warm Start The NPort S8000 is rebooted, such as when network parameters
are changed (IP address, subnet mask, etc.).
Power Transition (OnOff)
The NPort S8000 is powered down.
Power Transition (OffOn)
The NPort S8000 is powered up.
DI1 (OnOff)
Digital Input 1 is triggered by on to off transition