CN2610 User’s Manual Setting Up Device Control
5-6
Setting Value Notes Necessity
TCP data port 950 – 965
The host uses this value to determine
which serial device to send data to.
These values are fixed, and cannot be
changed by the user.
Serial Port TCP Port No.
01 950
02 951
03 952
… …
16 965
Required
TCP command port 966 – 981 The host uses this Port value to
determine which device to send
commands to. These values are fixed,
and cannot be changed by the user.
Serial Port TCP Port No.
01 966
02 967
03 968
… …
16 981
Required
TCP alive check time 0 – 99 min. The time period CN2610 waits before
checking if the TCP connection is alive
or not. If no response is received,
CN2610 will reset the port and terminate
the connection.
Optional
5. Press Esc to return to the PORT MENU.
Configuring RAW Mode
RAW mode is used for standard TCP/IP socket programs. RAW mode provides a transparent
communication link between the network socket program and the corresponding serial port.
1. Move the cursor to the Mode column for the port and press Enter.
CN2610-8 CN2610-8_19 V2.0
------------------------------------------------------------------------------
[Mode] Line mOdem Welcome_MSG Quit
Examine/modify the operation mode of async ports
ESC: back to menu Enter: select
Port Application Mode Description/more setting
01 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
02 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
03 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
04 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
05 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
06 [Device Control ] [ASPP ] [Async Server Proprietary Protocol]
07 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
2. Use the arrow keys to highlight RAW, and then press Enter.