User`s manual
CN2610 User’s Manual Setting Up Multiplexor
13-3
Selecting the Application
The Multiplex application uses two Async Servers. One of the servers (called the “host” CN2610)
is attached to a host with a multi-port serial board and mutiple serial lines. The other server (called
the “device” CN2610) is connected to external serial devices. In this way, one host can use a
TCP/IP connection to control multiple serial devices from a remote location. We use ports 5, 6, 7,
and 8 on both CN2610’s to illustrate.
Router
Switch
Code Reader
RS-232
RS-232
IBM workstation
with multiport board
POS
CN2610
CN2610
TCP/IP
TCP/IP
Router
Equipment
Rx
Tx
1 2 3 4 5 6 7 8 9 10111213141516
Reset
Ready
SELMENU
CN2610
16 port RS-232 Async Server
Rx
Tx
12345678910111213141516
Reset
Ready
SELMENU
CN2610
16 port RS-232 Async Server
NOTE
Configure the “Host” CN2610’s serial ports for RTELNET mode, and configure the “Device”
CN2610’s serial ports for TERM_BIN mode.
Configuring the “Host” CN2610
Open Port Menu Æ Mode to select the Multiplex application.
1. From the MAIN MENU, select Port, and then press Enter.
CN2610-8 CN2610-8_19 V2.0 MAIN MENU
------------------------------------------------------------------------------
Server [Port] seTting sAve Utility Restart Exit
Examine/modify async server ports configuration
Enter: select ESC: previous menu
2. From the PORT MENU, select Mode, and then press Enter.