User's Manual Network Device NE-4100

NE-4100 Series User’s Manual Web Console Configuration
6-9
Flow control
Setting Factory Default Necessity
None, RTS/CTS, DTR/DSR, XON/XOFF RTS/CTS Required
FIFO
Setting Factory Default Necessity
Enable, Disable Enable Required
NE-4100’s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. Disable the FIFO
setting when your serial device does not have a FIFO to prevent data loss during communication.
Operating Settings
Click on the Operating Settings link on the left side of the screen to display operating settings.
Make necessary changes to the settings and then click on Submit to validate the modifications.
TCP Server Mode
TCP alive check time
Setting Factory Default Necessity
0 to 99 min 7 min Optional
0 min: TCP connection is not closed due to an idle TCP connection.
1 to 99 min: NE-4100 automatically closes the TCP connection if there is no TCP activity for the
given time. After the connection is closed, NE-4100 starts listening for another host’s TCP
connection.
Inactivity time
Setting Factory Default Necessity
0 to 65535 ms 0 ms Optional
0 ms: TCP connection is not closed due to an idle serial line.
0-65535 ms: NE-4100 automatically closes the TCP connection if there is no serial data activity
for the given time. After the connection is closed, NE-4100 starts listening for another host’s TCP
connection.
This parameter defines the maintenance status as Closed or Listen on the TCP connection. The
connection is closed if there is no incoming or outgoing data through the serial port during the
specific Inactivity time.
If the value of inactivity time is set to 0, the current TCP connection is maintained until there is a
connection close request. Although inactivity time is disabled, the NE-4100 will check the
connection status between the NE-4100 and remote host by sending “keep alive” packets