User`s guide

NE-4100 Series Serial Command Mode User’s Guide
Page 21
Example 1: Get Model Name using HW Trigger
STEP 1: Configure trigger mode to HW trigger (Chap. 4).
STEP 2: Check NE’s serial port settings (Chap. 5).
STEP 3: Start Windows HyperTerminal and set PC’s serial port settings to the same settings
recorded in STEP 2.
STEP 4: Pull NE’s GPIO 0 to Low to enter Serial Command Mode.
STEP 5: HyperTerminal displays “<E” (indicates NE is in Serial Command Mode).
STEP 6: Use HyperTerminal to send “>RBN\n” (command to request NE’s Model Name).
STEP 7: HyperTerminal displays ”<YBNNE-4100-CMD\r” (indicates NE’s Model Name =
NE-4100T-CMD).
STEP 8: Use HyperTerminal to send “>WBR1\n” (command to exit Serial Command
Mode).
NOTE
When using MOXA PComm Terminal, instead of HyperTerminal, use “CR” (carriage return) in
place of “Enter”.
Example 2: Change IP Address using HW Trigger
STEP 1: Configure trigger mode to HW trigger (Chap. 4).
STEP 2: Check NE’s serial port settings (Chap. 5).
STEP 3: Start Windows HyperTerminal and set PC’s serial port settings to the same settings
recorded in STEP 2.
STEP 4: Pull NE’s GPIO 0 to Low to enter Serial Command Mode.
STEP 5: HyperTerminal displays “<E” (indicates NE is in Serial Command Mode).
STEP 6: Use HyperTerminal to send “>WNP192.168.127.253\n” (set IP address to
192.168.127.253).
STEP 7: HyperTerminal displays ”<YNP\r” (indicates command was executed successfully).
STEP 8: Use HyperTerminal to send “>WBR2\n” (saves changes and restarts NE Module).
STEP 9: Repeat STEP 1 to STEP 5.
STEP 10: Use HyperTerminal to send “>RNP\n” (command to request NE’s IP Address).
STEP 11: HyperTerminal displays “<YNP192.168.127.253\r” (indicates IP address =
192.168.127.253).
STEP 12: Use HyperTerminal to send “>WBR1\n” (command to exit Serial Command
Mode).
NOTE
When using MOXA PComm Terminal, instead of HyperTerminal, use “CR” (carriage return) in
place of “Enter”.