User`s guide
NE-4100 Series Serial Command Mode User’s Guide
Page 10
NOTE
1. The default setting is HW Trigger Enabled.
2. Only one of the two trigger types (HW or SW) can be set at the same time.
Telnet Console
The Telnet Console provides a convenient text-based utility to configure your NE-4100-CMD.
Keep in mind that if you are using Telnet to access a Network Enabler connected to the same LAN
as your PC, the Network Enabler and PC must be on the same subnet.
1. From the DOS command prompt, type telnet 192.168.127.254 (use the correct IP address if
different from the default), and then press enter to access NE-4100-CMD’s telnet console.
2. The Telnet Console is easy to use. To select an option, type the character next to the option
and then press Enter. For example, type 5 to select Serial Command Mode setting.
3. Once all configurations have been made, return to the main Telnet menu, and then type s to
save the configuration and restart the NE-4100-CMD. If you quit without saving, any
changes you made to the configuration will be lost.