Specifications

4-18
www.moxa.com
info@moxa.com
MGate™ 5101-PBM-MN Series
Overview
Various Maintenance Functions
Windows Utility for Easy Conguration and Trafc Monitoring
Redundant Power Inputs
Specifications
MGate™ 5101-PBM-MN Series
1-port PROFIBUS-to-Modbus TCP gateways
The MGate 5101-PBM-MN gateway provides a communication portal
between PROFIBUS devices (e.g. PROFIBUS drives or instruments)
and Modbus TCP hosts. All models are protected with a rugged
metallic casing, DIN-rail mountable, and offer optional built-in optical
The MGate Manager utility provides a user friendly interface to make
configuration and operation as easy as possible. Moxa’s innovative
AutoScan function can automatically detect all connected PROFIBUS
slave devices and their available I/O modules to quickly complete
gateway configuration, after which an easy to read data mapping
table is created to assist in the configuration of Modbus TCP master
(e.g. SCADA, PLC) settings. In addition, users can configure import/
export maintenance functions, and use embedded monitoring tools
to maintain Modbus communication packets logs, which can used for
troubleshooting.
isolation. The PROFIBUS and Ethernet status LED indicators are
provided for easy maintenance. The rugged design is suitable for
industrial applications such as oil/gas, power, process automation, and
factory automation.
The MGate 5101-PBM-MN provides Web console and Telnet console
for remote maintenance. Each also supports encryption commutation
functions such as HTTPS and SSH for preventing unauthorized access.
The log functions are provided in firmware such as connection event
of Modbus or PROFIBUS for maintenance. Users can monitor each
I/O data and review the log through the web console remotely. A
relay output alarm is provided for the power input status. It gives
maintenance engineers an additional tool for troubleshooting and
maintenance.
The MGate 5101-PBM-MN has dual power inputs for greater reliability.
The power inputs allow simultaneous connections to two live DC
power sources to provide uninterrupted operation even if one power
Protocol conversion between PROFIBUS and Modbus TCP
Automatic scan of PROFIBUS devices for easy conguration
Redundant dual DC power inputs and relay output supported
Embedded data packet analyzer and diagnostic tool
Web-based GUI for I/O data visualization
-40 to 75°C wide operating temperature models available
source fails. The higher level of reliability makes these advanced
PROFIBUS master to Modbus TCP gateways ideal for demanding
industrial applications.
Ethernet Interface
Number of Ports: 1
Speed: 10/100 Mbps, Auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 kV (built-in)
Modbus TCP
Operation Modes: Modbus TCP Slave/Master
PROFIBUS Interface
Protocol: PROFIBUS DP-V1 Master
Number of Ports: 1