User`s manual
MGate MB3000 User’s Manual Getting Started
2-11
MGate MB3480
STEP 1: Attach the fix ribs onto the unit with screws.
16.9 cm
2.5 cm
4 mm
STEP 2:
Position four screws on the wall, with each screw at the corner of a rectangle 16.9 cm across and
2.5 cm high. Make sure the heads are 6 mm in diameter or less, with shafts at 3 mm in diameter
or less. Tighten the screws but leave about 5 mm of space between the head and the wall.