ioLogik W5340
Active GPRS I/O with 4 AIs, 8 DIOs, and 2 relay outputs
Specifi cations
GPRS, Ethernet LAN, RS-232/422/485 supported ›
Smart Active GPRS connection ›
Low power consumption ›
Secure wake on call ID ›
Active messaging with real-time stamp ›
SNMP Trap with I/O status ›
Data logging with SD card ›
Unicode Active Messaging with real-time stamp, including ›
SMS, SNMP Trap with I/O status, TCP, email
ioAdmin and Active OPC Server supported ›
Windows/WinCE VB/VC.NET and Linux C APIs ›
Introduction
The ioLogik W5340 is designed for cellular remote monitoring and
alarm systems, such as automated river monitoring and pipeline
monitoring. The ioLogik W5000 series uses GPRS technology to
maximize the coverage of remote monitoring applications. This kind of
application needs cellular communications and I/O points connected to
various sensors, including rainfall meters, flow meters, and water level
detectors, since installing devices is usually difficult. They all enjoy the
benefit of the GPRS communication feature of ioLogik W5340.
Cellular
Interface: GPRS
Band Options: Quad-band 850/900/1800/1900 MHz
GPRS Multi-Slot Class: Class 10
GPRS Terminal Device Class: Class B
SMS: Point-to-Point Text/PDU
SIM Control Voltage: 3 V
LAN
Ethernet: 1 x 10/100 Mbps, RJ45
Protection: 1.5 KV magnetic isolation
Protocols: Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP, SNTP
Serial Communication
Interface: 1 x RS-232/422/485, software selectable
(9-pin D-Sub, male or 5-contact terminal block)
Baudrate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
bps
Analog Input
Channels: 4 analog inputs with differential input
Resolution: 16 bits
I/O Mode: Voltage / Current
Input Range: 0 to 10 V, ±10 V, ±5 V, 0 to 20 mA, 4 to 20 mA
Accuracy:
• ±0.1% FSR @ 25°C
• ±0.3% FSR @ -10 and 55°C
Sampling Rate (all channels): 100 samples/sec
Input Impedance: 200K ohms (min.)
Built-in Resistor for Current Input: 102 ohms
DI/DO Confi gurable Channels
Channels: 8
I/O Mode:
• DI or Event Counter (up to 900 Hz)
• DO or Pulse Output (up to 100 Hz)
Digital Input
Channels: Up to 8, source/sink selectable
Sensor Type: NPN/PNP type
I/O Mode: DI or Event Counter (up to 900 Hz)
Dry Contact:
• Logic 0: short to GND
• Logic 1: open
Wet Contact: (For Source Type)
• Logic 0: 0 to 3 VDC
• Logic 1: 10 to 30 VDC (DI COM to DI)
Common Type: 4 points per COM
Isolation: 3K VDC or 2K Vrms
Counter/Frequency: 900 Hz, power off storage
Digital Filtering Time Interval: Software selectable
Over-voltage Protection: 36 VDC
Poweroff Counter Memory: 48 bytes
Digital Output
Channels: Up to 8, sink type, 36 VDC, 200 mA
I/O Mode: DO or Pulse Output (up to 100 Hz)
Pulse Wave Width/Frequency: 10 ms/100 Hz
Over-voltage Protection: 45 VDC
Over-current Limit: 600 mA
The certifi cation logos shown here apply to some or all of the products in this