Industrial I/O Product Selection Guides Stand-alone Type I/Os . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2 Modular Type I/Os . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 Industrial I/O Introduction to Industrial I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Remote Monitoring Solutions Stand-alone Type I/Os 5 Industrial I/O > Product Selection Guides Model ioLogik W5340 ioLogik E2210 ioLogik E2212 ioLogik E2214 ioLogik E2240 ioLogik E2242 Category Cellular GPRS I/O Active Ethernet I/O Active Ethernet I/O Active Ethernet I/O Active Ethernet I/O Active Ethernet I/O Comm.
Industrial Networking Solutions Introduction to Industrial I/O Intelligent, high-performance, reliable I/O modules for automation 5 Industrial I/O > Introduction to Industrial I/O Moxa’s ioLogik series of industrial I/O products are intelligent, highperformance, reliable remote I/O solutions that bring the ease of open-standard Ethernet/TCP and serial RS-232/485 communications to automation applications, including data acquisition, and remote monitoring and alarm systems.
Remote Monitoring Solutions Active Ethernet I/O The Most Intelligent I/O for Remote Monitoring and Alarm Applications 5 ioLogik also supports Active Ethernet I/O, which is a new concept introduced by Moxa that offers proactive, condition-based reporting and the control of I/O devices used for PC-based data acquisition and control. The I/O status of an Active Ethernet I/O device can be reported and controlled automatically on-site based on user specified conditions.
Industrial Networking Solutions Push Technology for Events and Alarms Active Messaging TCP/UDP Message + Time Stamp SNMP Trap + Time Stamp DO-Stir Machine hine RTD1 RTD2 RTD3 DO Heater e-mail + Time Stamp 39˚C 42˚C 45˚C Active Ethernet I/O can be used to generate alarms when an event (user-defined by Click&Go) is triggered. Standard TCP or UDP packets can be sent to a central host, SNMP traps can be sent to IT monitoring systems, and e-mail/SMS messages can be sent to the site maintainer.
Remote Monitoring Solutions Solution-oriented Design Dual-LAN Redundancy Primary Host LAN 1 LAN 2 5 Backup Host Peer-to-Peer Communication over Ethernet Industrial I/O > Introduction to Industrial I/O Easy Expansion with Slice-type Modules Slice Type I/O Modules The ioMirror E3000 series of Ethernet I/O products are designed as cable replacement solutions that send input signals to remote outputs over an IP network.
Industrial Networking Solutions Wireless I/O Integrating I/O and GPRS Communications Active GPRS I/O is a highly integrated solution that combines GPRS communications, front-end intelligence, and a front-end data logging function for information analysis and prediction. By using GPRS technology, the ioLogik W5000 series gives remote monitoring applications maximum coverage.
Remote Monitoring Solutions The Benefits of Integration ioLogik Active Wireless I/O provides an integrated solution with a number of important benefits. Easy to Install Extra Power Savings Caller ID for Security Needs only a Sliver of Bandwidth 5 Easy Installation Industrial I/O > Introduction to Industrial I/O By supporting Moxa’s powerful Active OPC Server, Active GPRS I/O products can be easily integrated with your SCADA system.
Industrial Networking Solutions Secure Wake on Call There are three ways to wake up an ioLogik Active GPRS I/O. The first is wake up by event, such as with an active message, SMS, email, or SNMP Trap. The second is wake on call. In this case, the ioLogik W5340 can be woken by a secure caller ID. In sleep mode, the ioLogik W5340 will disconnect all communications except GSM. The only way you can connect is with wake on call.
Remote Monitoring Solutions Common Specifications for ioLogik E2000 Series Active Ethernet I/O Products LAN Power Consumption: 282 mA typical @ 24 VDC Physical Characteristics Ethernet: 1 x 10/100 Mbps, RJ45 Protection: 1.5 KV magnetic isolation Protocols: Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP (MIB for I/O and Network), HTTP, CGI, SNTP Wiring: I/O cable max.
Industrial Networking Solutions Active OPC Server Lite Seamlessly connect ioLogik to your SCADA system › OPC DA 3.
Remote Monitoring Solutions Dynamic IP/WAN Connection Unlike the fixed IP requirements of Ethernet I/O with a traditional OPC server, Active OPC Server Lite and ioLogik products provide the flexibility of configuring the ioLogik to use dynamic IP addresses. The ioLogik connects directly to the Active OPC Server Lite instead of being polled, which makes dynamic IP addressing and WAN Access to the Ethernet I/O device possible, and adds even greater flexibility by allowing connections across firewalls.
Industrial Networking Solutions Click&Go Easy and intuitive I/O control configuration for the ioLogik Active Ethernet I/O › PC-free solution with local intelligence › Programming-free IF-THEN-ELSE logic reduces setup time › Time stamped active alarm report with TCP, UDP, SNMP Trap, email, SMS, or CGI commands › Time-based scheduler and timer control › Input-to-output control over IP with peer-to-peer and remote action PC-free Alarm and Control Solution Moxa’s own Click&Go™ logic turns your ioLogik E2000,
Remote Monitoring Solutions Click&GoTM Provides Time-based Scheduler and Timer Control Click&Go™ can be scheduled to perform user defined tasks such as output control, remote actions, and active messaging. This function is useful when applied to energy savings, lighting control, and water pumping systems. The timer function allows users to set a delay period for actions, which is particularly useful when used with alarm systems for which users need an authentication period to avoid false alarms.
Industrial Networking Solutions ioLogik E2210 Active Ethernet I/O with 12 digital inputs and 8 digital outputs › Instant event messaging by TCP/UDP/email/SNMP-trap › Easy-to-use Click&Go™ Logic for local output control › 12-point 24 VDC digital input with counter › 8-point 24 VDC digital output with pulse output › PC-based configuration utility and web console › I/O control over Modbus/TCP and SNMP protocol › Windows/WinCE VB/VC.
Remote Monitoring Solutions ioLogik E2212 Active Ethernet I/O with 8 digital inputs, 8 digital outputs, and 4 configurable DIO › Selectable digital I/O combination (by software) › Accepts PNP or NPN sensors › DI counter saved automatically when power shuts off › Instant event messaging by TCP/UDP/email/SNMP trap › Easy-to-use Click&Go™ Logic for local output control › PC-based configuration utility and web console › I/O control over Modbus/TCP and SNMP protocol › Windows/WinCE VB/VC.
Industrial Networking Solutions ioLogik E2214 Active Ethernet I/O with 6 digital inputs and 6 relay outputs › 6 DIs supporting PNP, NPN, and dry contact › 6 Form A relay outputs (Normal Open) › Relay specifications: 5 A @ 250 VAC, 5 A @ 30 VDC › Instant event messaging by TCP/UDP/email/SNMP-trap › DI and Relay counter saved when the power is shut off › PC-based configuration utility and web console › Power On default relay status setting with sequence › Easy-to-use Click&Go™ Logic for local output control
Remote Monitoring Solutions ioLogik E2240 Active Ethernet I/O with 8 analog inputs and 2 analog outputs › 8-channel analog inputs for voltage, current signal › 2-channel analog outputs for voltage, current actuator control › Instant event messaging by TCP/UDP/email/SNMP-trap › Easy-to-use Click&Go™ Logic for local output control › PC-based configuration utility and web console › Windows/WinCE VB/VC.
Industrial Networking Solutions ioLogik E2242 Active Ethernet I/O with 4 analog inputs and 12 configurable DIOs › 4 fixed differential analog input channels › 12 configurable digital input/output channels › DI counter saved automatically when power shuts off › Instant event messaging by TCP/UDP/email/SNMP-Trap › PC-based configuration utility and web console › Easy-to-use Click&Go™ Logic for local output control › Windows/WinCE VB/VC.
Remote Monitoring Solutions ioLogik E2260 Active Ethernet I/O with 6 RTD inputs and 4 digital outputs › Supports PT, JPT, Ni RTD sensor types and resistors › Adjustable RTD sampling rate › Instant event messaging by TCP/UDP/email/SNMP-trap › PC-based configuration utility and web console › Easy-to-use Click&Go™ Logic for local output control › Windows/WinCE VB/VC.
Industrial Networking Solutions ioLogik E2262 Active Ethernet I/O with 8 thermocouple inputs and 4 digital outputs › Supports J, K, T, E, R, S, B, and N type thermocouple and mV modes › Conversion Time: Less than 90 ms › Instant event messaging by TCP/UDP/email/SNMP-Trap › PC-based configuration utility and web console › Easy-to-use Click&Go™ Logic for local output control › Windows/WinCE VB/VC.
Remote Monitoring Solutions ioMirror E3210 Ethernet Peer-to-Peer I/O with 8 digital inputs and 8 digital outputs › Direct input-to-output signal communication over IP › High speed Peer-to-Peer I/O within 20 ms › One physical alarm port for connectivity status › Quick and easy utility and web-based settings › Local alarm channel › Remote alarm message › Supports Modbus/TCP for remote monitoring › Optional LCD module for simple setting 5 Industrial I/O > ioMirror E3210 The certification logos shown here a
Industrial Networking Solutions Physical Characteristics Warranty Wiring: I/O cable max. 14 AWG Warranty Period: 2 years Details: See www.moxa.
Remote Monitoring Solutions ioLogik E4200 Modular Active Ethernet I/O adaptor › Supports up to 16 I/O modules › Dual Ethernet LANs and one RS-232 port › Front-end intelligence that supports 80 Click&Go rules › Unicode Active Messaging with real-time stamp, including SMS, SNMP Trap with I/O status, TCP, email › Built-in web console › PC utility: Auto detection of installed modules › Windows/WinCE VB/VC.
Industrial Networking Solutions NA-4010 Ethernet network adaptor ioLogik 4000 System Power (5 VDC) System Power (GND) Modbus TCP/IP NA-4010 SYS LINK ACTIVE I/O Field Power System Bus Non-isolation Switching Power 0 1 24V 0V System Power (0 VDC) System Power (24 VDC) 2 3 Shielding Ground 4 5 0V 0V Field Power (0 VDC) 6 7 Field Power (24 VDC) 24V 24V Field Power (0 VDC) Field Power (24 VDC) The certification logos shown here apply to some or all of the products in this section.
Remote Monitoring Solutions LDP1602 LCD Module Snap-on module for the ioLogik 2000 and ioMirror 3000 series › Hot-pluggable display module for ioLogik Active Ethernet I/O, serial I/O, and Peer-to-Peer I/O › Easy, portable configuration kit for IP display and configuration › Direct display for analog value and digital input, counter status › No battery required (powered through the I/O ) 5 Industrial I/O > LDP1602 LCD Module The certification logos shown here apply to some or all of the products in this
Industrial Networking Solutions ioLogik W5340 Active GPRS I/O with 4 AIs, 8 DIOs, and 2 relay outputs › GPRS, Ethernet LAN, RS-232/422/485 supported › Smart Active GPRS connection › Low power consumption › Secure wake on call ID › Active messaging with real-time stamp › SNMP Trap with I/O status › Data logging with SD card › Unicode Active Messaging with real-time stamp, including SMS, SNMP Trap with I/O status, TCP, email › ioAdmin and Active OPC Server supported › Windows/WinCE VB/VC.
Remote Monitoring Solutions Regulatory Approvals Over-temperature Shutdown: 160°C Output Current Rating: Max.
Industrial Networking Solutions ioLogik R2110 RS-485 remote I/O with 12 digital inputs and 8 digital outputs › 12-channel 24 VDC digital inputs with DI Event Counter mode, and software selectable filtering time › 8-channel 24 VDC digital outputs with pulse output mode and software selectable pulse width › LED indicators for all I/O channels › Over-temperature protection (up to 175°C) › Over-current protection (400-mA/channel) › Easy-to-use, quick programming library for VB, VC++, BCB, .
Remote Monitoring Solutions ioLogik R2140 RS-485 remote I/O with 8 analog inputs and 2 analog outputs › 8 analog input channels for millivolts (mV), voltage, and current signal with wire-off detection (at 4 to 20 mA) › 2-channel analog outputs for voltage, current actuator control › 16-bit resolution analog inputs, 12-bit resolution analog output › Easy-to-use, quick programming library for VB, VC++, BCB, .
Industrial Networking Solutions NA-4020/4021 RS-485 or RS-232 network adaptors ioLogik 4000 System Power (5 VDC) System Power (GND) Modbus RS-485 NA-4020 SYS TxD RxD I/O Field Power System Bus Non-isolation Switching Power 0 1 24V 0V System Power (0 VDC) System Power (24 VDC) 2 3 Shielding Ground 4 5 0V 0V Field Power (0 VDC) 6 7 24V 24V Field Power (24 VDC) Field Power (0 VDC) Field Power (24 VDC) The certification logos shown here apply to some or all of the products in this section.
Remote Monitoring Solutions Modular Remote I/O Selection Guide I/O Modules DC-Digital Inputs Model Channels Specs Sink/Source Connector Voltage AC-Digital Inputs M-1800 M-1801 M-1600 M-1601 M-1450 8 8 16 16 4 4 Sink Source Sink Source --- --- RTB RTB 20-pin 20-pin RTB RTB 24 VDC 24 VDC 24 VDC 24 VDC 110 VAC 220 VAC Isolation Optical isolation Digital Outputs 5 Model Channels Sink/Source Specs Connector M-2800 M-2801 M-2600 M-2601 8 8 16 16 4 Sink Source Si
Industrial Networking Solutions Digital Input Modules 8-channel 24 VDC digital input modules M-1800 Status 0 4 System Power (5 VDC) System Power (GND) System Bus 1 5 2 6 3 7 0 1 CH0 CH1 2 3 CH2 CH3 4 5 CH4 CH5 6 7 CH6 CH7 Inputs per Module: 8 channels, sink type On-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDC Min. Off-state Voltage: Max. 5 VDC On-state Current: Max. 6 mA/point @ 28.8 VDC Input Impedance: Typ. 5.1K ohms Filtering Time: Typ. 1.
Remote Monitoring Solutions M-1601: 16 digital inputs, source, 24 VDC M-1601 System Power (5 VDC) System Power (GND) Status 0 4 8 12 Inputs per Module: 16 channels, source type On-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDC Min. Off-state Voltage: Max. 5 VDC On-state Current: Max. 6 mA/point @ 28.8 VDC Input Impedance: Typ. 5.1K ohms Filtering Time: Typ. 1.5 ms Common Type: 16 channels for 2 COMs Power Consumption: Max.
Industrial Networking Solutions Digital Output Modules 8-channel 24 VDC digital output modules M-2800: 8 digital outputs, sink, 24 VDC, 0.5 A M-2800 System Power (5 VDC) System Power (GND) Status 0 4 Outputs per Module: 8 channels, sink type Output Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDC On-state Voltage Drop: Max. 0.3 VDC @ 25°C On-state Current: Min. 1 mA per channel Off Leakage Current: Max. 50 µA Output Current Rating: Max. 0.
Remote Monitoring Solutions M-2601: 16 digital outputs, source, 24 VDC, 0.3 A M-2601 Status 0 4 8 12 System Power (5 VDC) System Power (GND) Outputs per Module: 16 channels, source type Output Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDC On-state Voltage Drop: Max. 0.3 VDC @ 25°C On-state Current: Min. 1 mA per channel Off Leakage Current: Max. 50 µA Output Current Rating: • Max. 0.3 A per channel • Max.
Industrial Networking Solutions Analog Input Modules 8-channel analog input modules, 12-bit resolution M-3802 M-3802 Status Status M-3802: 8 analog inputs, 4 to 20 mA, 12 bits M-3810: 8 analog inputs, 0 to 10 V, 12 bits M-3810 Status Resolution in Ranges: 12 bits, 2.44 mV/bit Input Current Range: 0 to 10 VDC Data Format: 16-bit integer (2’s complement) Accuracy: • ±0.1%, FSR @ 25°C • ±0.3%, FSR @ 0°C, 60°C Input Impedance: 500K ohms Conversion Time: 4 ms for all channels Power Consumption: Max.
Remote Monitoring Solutions Temperature Input Modules 2-channel temperature input modules, RTD or thermocouple input M-6200: 2 analog inputs, RTD: PT100, JPT100 Sensor Types: • PT50, PT100, PT200, PT500, PT1000 (resistance 100 milli-ohms/bit) • JPT100, JPT200, JPT500, JPT1000 (resistance 10 milli-ohms/bit) • NI100, NI200, NI500, NI1000, NI120, CU10 (resistance 20 milli-ohms/bit) Resolution: 0.1°C/10 milli-ohms Data Format: 16-bit integer (2’s complement) Accuracy: • ±0.1%, FSR @ 25°C • ±0.
Industrial Networking Solutions Analog Output Modules 4-channel analog output modules, 12-bit resolution M-4402: 4 analog outputs, 4 to 20 mA, 12 bits Status M-4410: 4 analog outputs, 0 to 10 V, 12 bits Resolution in Ranges: 12 bits, 2.44 mV/bit Output Current Range: 0 to 10 VDC Data Format: 16-bit integer (2’s complement) Accuracy: • ±0.1%, FSR @ 25°C • ±0.3%, FSR @ 0°C, 60°C Output Impedance: Max. 5K ohms Conversion Time: 2 ms for all channels Power Consumption: Max.
Remote Monitoring Solutions Power Modules When to Use a Power Module System Power Distributor 5 The system power expansion module is designed to provide extra power for connected I/O expansion modules. Each NA-4000 series network adaptor can provide 1.5 A @ 5 VDC. If you need more power for your installed I/O expansion modules, you will need to use an M-7001 module. However, note that the M-7001 can only provide 1.5 A @ 5 VDC. M-7001 Industrial I/O > Power Modules .....
Industrial Networking Solutions Power Modules M-7001: System power module M-7002: Field power module M-7002 M-7001 System Power (5 VDC) System Power (GND) System Power (5 VDC) System Power (GND) System Bus System Bus Non-isolation Switching Power *Field Power ranging from 24/48 VDC to 110/220 VAC 0 1 0 1 System Power Input (0 VDC) 24V 0V System Power Input (24 VDC) 2 3 CG CG 2 3 CG CG Shield Ground Shield Ground 4 5 0V 0V Field Power Input (0 VDC) 4 5 N N Field Power Input (N) 6 7 24V 2
Remote Monitoring Solutions Modular I/O Accessories TB 1600 DIN-Rail mounting screw terminal module with 20-pin connector • • • • • 5 20 pins, one-to-one assignment Connector pitch: 3.81 mm DIN-Rail mounting type Dimensions: 77.5 x 67.5 x 51 mm (3.05 x 2.66 x 2.