User`s manual

Software Installation
Intellio C218Turbo User's Manual 3-15
6. Restart Windows 95/98 system.
Note ! The latest configuration will not take effect unless the system restarts.
Note ! Please double check if all the C218Turbo components: Control
Board, link cable and external cable/box, are connected and fastened
tightly in order to ensure the system and driver will start successfully
later.
7. When system restarts, all the error conditions of the board will be popped
up onto the screen if any. Otherwise, everything should be fine.
If error message like “C218Turbo at base memory [C8000] is absent or occupied
by others!” or “MOXA C218Turbo at base memory [C8000] interrupt failure!
appears, refer to Chapter “Troubleshooting” for solutions.
Note ! Once the board and driver are installed and the system restarts
successfully, you can start to develop applications by using PComm
library (See Chapter “Serial Programming Tools”) or using Microsoft
Win32 API. Also you can execute any ready-made application such as
PComm utility Terminal emulator (See Chapter “Serial Programming
Tools”) or HyperTerminal to transmit/receive data as well as Remote
Access Service to provide dial-up networking capability.
Configuring Board and Port
If you already have installed the driver and want to re-configure the C218Turbo
board and ports, add more boards or delete boards under Windows 95/98, the
following is the procedure for you.
1. Click on the Taskbar [Start] button, then select [Programs] menu, then [MOXA
Utilities] menu and then [MOXA Configuration Panel] icon.
2. The configuration panel will be popped up. Please see steps 4-7 in the previous
Section “Driver Installation” for more details.