User`s manual

Hardware Installation
Intellio C218Turbo User's Manual 2-3
Note ! Make a note of the selected IRQ number and base memory
address for software driver configuration.
Step 5: Remove the slot cover bracket if present.
Step 6: Plug the C218Turbo Control Board firmly into any free 16-bit ISA slot.
Step 7: Fasten the holding screw to make the Control Board fixed.
Step 8: Replace the system cover.
Step 9: Connect one of the connection box/cable (also adapter if required) detailed
in the next section, “Installing Connection Option Opt8x”.
Step 10: Power on PC.
Step 11: Proceed with software installation detailed in the next Chapter “Software
Installation”.
Installing Connection Option Opt8x
Connect the C218Turbo with the one of the following connection options. Then
you can connect your modem, serial printer, PC COM1/2, bar code reader, POS,
instrument or any other serial devices to the DB25/DB9 connectors. Refer to Chapter
“Connection Option (Opt8x) and Cable Wiring” for RS-232/RS-422/RS-485 cable
wiring.
Opt8A/Opt8B/Opt8S
Hold one end of the DB62 cable and plug it into the DB62 connector on the bracket
of the C218Turbo. Carefully screw it until it is tight. Then plug the other end of the
cable to the RS-232 connection box's DB62 connector. Both ends of the cable are
identical.