User`s manual
Software Installation
Intellio C218Turbo /PCI User's Manual 3-15
Port Configuration Stage
This stage displays the “MOXA Ports Installation” dialog box for the port
configuration. Here you can map the MOXA ports to the system COM numbers.
In the “C218Turbo/PCI Installation” dialog box, you can map the physical ports to
COM numbers in two ways depending on the “Auto Enumerating COM number”
check box.
Sequential Port Mapping: (Enable “Auto Enumerating COM number”)
Specify the COM number of the first port and subsequent ports are mapped to
continuous COM numbers. For instance, if first port is mapped to COM10, then
second port is mapped to COM11 sequentially.
Non-sequential Port Mapping: (Disable “Auto Enumerating COM number”)
Specify the COM number for individual port. For instance, the second port can
be out of sequence, say COM18, while the first port is mapped to COM10.
In addition, in the “C218Turbo/PCI Installation” dialog box, you may click on
[Advanced Settings] button to tune the advanced features, “UART FIFO” and
“Transmission Mode”, for each port for particular performance requirements.