User`s manual

Hardware Installation
Intellio C320Turbo User's Manual 2-9
l Now the installation of the external Basic/Extensive module is complete.
Continue to install the software driver explained in chapter 3.
Operating LED Indicators
After completing the installation and powering on the CPU/Basic Module and the PC
system, check the two-digit LED display on the CPU/Basic Module. These LEDs
show the results of the system self-diagnostic tests which are run by the CPU/Basic
Module after startup.
The CPU/Basic Module will first test the ROM and RAM of itself, and then
UART/Extensive Module(s) if present. If any error is found, the LED display will
show one of the messages described in Troubleshooting chapter.
If the first test passed, the CPU/Basic Module will then display "Ld" waiting for
loading firmware from the Intellio C320Turbo Control Board. After loading the
firmware, the CPU Module will scan for the number of UART Modules or the number
of ports available. The LED will show the last accessible port.
CPU Module
The left digit shows the UART Module number and the right digit shows the last
port number within a UART Module. The UART Module closest to the CPU Module
is of number 1. The next module is of number 2, and so on. For example, if 48 is
displayed, it means that the last accessible port is the eighth port of the fourth UART
Module.
Multiport Controller with Rack Mount Kit installed ( Rear View )
L-type Plate
L-type Plate
Screw