User`s manual
6-8 Intellio C320Turbo User's Manual
This indicates MOXA board is found but the IRQ is conflicting with other
adapter. Make sure there is no conflict with other adapter's IRQ. Check the PCI
BIOS IRQ setting and make sure the IRQ is available.
7. Error message “C320twin.cod file not found!” appears.
Error message “C320twin.cod file length is wrong!” appears.
Error message “C320twin.cod file data content error!” appears.
It means something is wrong with driver installation or the file has been deleted
accidentally or corrupted somehow. To recover, simply reinstall the driver.
UNIX
This section is specific for troubleshooting under UNIX. For general problems and
solutions, please see the previous “General Troubleshooting” section.
1. During system reboots, error message “WARNING! C320Turbo (XX000) not
found!” appears.
The possible cause is memory conflict or defective board. Please shutdown the
system first, and then refer to the problem 1 for solutions in the previous “General
Troubleshooting” section.
2. During system reboots, error message “ERROR! C320Turbo
(MemBank=XX000) download failed!” appears.
The possible cause is memory conflict or defective board. Please shutdown the
system first, and then refer to the problem 1 for solutions in the previous “General
Troubleshooting” section.
3. MOXA port responds too slowly or abnormal key operation.
The applications are not compatible with the Intellio C320Turbo On-board line
discipline. The only way to work it around is to set On-board line discipline
feature to “Disable” in [Board] sub-menu of Advanced configuration (the
“UNIX” section of the “Software Installation” chapter).
4. When respawning quite a few number of tty ports, the following error messages