User`s manual

Industio CP-132 Series User’s Manual
3-6
9. Click [OK] in the “Port #” and “Property” dialog boxes to go back to the “MOXA
Smartio/Industio Configuration Panel” dialog box.
Note ! If you need to install more than one board, click [Add] and repeat steps 6
to 8 to configure the additional board. Up to four
Industio CP-132U Series boards
can be installed in one NT system.
Click [OK] to finish the configuration.
10. When you have finished the configuration, click on the [Close] button in the “Network
Settings” dialog box.
11. Restart the Windows NT system. The new configuration will take effect when the
system restarts.
Note ! The latest configuration will not take effect unless the system restarts.
12. Once the system restarts, you may check the event log issued by the MOXA driver to
see if the board’s ports have been initialized successfully.
Enter the [Administrative] group, click on the [Event Viewer] icon and select
[System Event Log] to check a message similar to “MOXA CP-132, with first
serial port COM3, has been enabled” for each configured board.