User`s manual

Troubleshooting
Industio CP-114 User's Manual 6-3
Windows 95/98
This section is specific for troubleshooting under Windows 95/98. For general problems and solutions,
please see the previous section, “General Troubleshooting”.
1. The system fails to find the
Industio
CP-114 board!
- The board(s) is not plugged properly.
- The slot for plugging the board is defective.
In this case, please try other slots until you find a good one.
- The board might be defective.
2. After the system reboots, the error message “CP-114 (BusNo=x, DevNo=x,
Port1=COMx) interrupt number is invalid!” appears.
This indicates that the MOXA board is found, but the IRQ is conflicting with other adapter. Make
sure MOXA boards IRQ is not conflicting with other adapters. Check the PCI BIOS IRQ
settings and select an available IRQ for MOXA boards.