3-6 Industio CP-114 User's Manual
Note ! The latest configuration will not take effect unless the system restarts.
11. Once the system restarts, you may check the event log issued by the MOXA driver to see if the
ports of the board are initialized successfully.
l Enter the [Administrative] group, click on the [Event Viewer] icon and select [Log]
and [System] to check a message similar to “MOXA CP-114, with first serial port
COM3, has been enabled” for each configured board.
l If an error message similar to “Cannot find any configured MOXA CP-114
board!appears, refer to the “Troubleshooting” chapter for solutions.
Note ! Once the board and the driver are installed and the driver restarts successfully, you
can start to develop applications with the
PComm
library (See “Serial
Programming Tools”) or the Microsoft Win32 API. You can also execute any
ready-made applications, such as
PComm
utility Terminal emulator (See “Serial
Programming Tools”) or HyperTerminal to transmit/receive data, as well as
Remote Access Service to provide dial-up networking capabilities.
Configuring Board and Port
If you already have installed the driver and want to re-configure the ports, please follow this procedure.
1. In the [Control Panel], click on the [Network] icon and select the [Adapters] tab.
2. Select “MOXA Smartio/Industio Family Adapter” in “Network Adapters”.