Installation guide

6
STEP 2:
Mounting Moxa Industrial Media Converter on the wall
requires 4 screws. Use the IMC, with wall mount plates
attached, as a guide to mark the correct locations of the 4
screws. The heads of the screws should be less than 6.0
mm in diameter, and the shafts should be less than 3.5
mm in diameter, as shown in the figure at the right.
NOTE
Test the screw head and shank size by inserting
the screw into one of the keyhole shaped
apertures of the Wall Mounting Plates, before it
is screwed into the wall.
Do not screw the screws in all the way—leave a space of
about 2 mm to allow room for sliding the wall mount
panel between the wall and the screws.
6.0 mm
3.5 mm
STEP 3:
Once the screws are fixed in the wall, insert the four screw heads through the
large parts of the keyhole-shaped apertures, and then slide Moxa Industrial
Media Converter downwards, as indicated below. Tighten the four screws for
added stability.
Wiring Requirements
WARNING
Do not disconnect modules or wires unless power has been
switched off or the area is known to be non hazardous.
The devices may only be connected to the supply voltage shown
on the type plate.
The devices are designed for operation with a safety extra-low
voltage. Thus, they may only be connected to the supply voltage
connections and to the signal contact with the safety extra-low
voltages (SELV) in compliance with IEC950/ EN60950/
VDE0805.
WARNING
Substitution of components may impair suitability for Class I,
Division 2 and Zone 2.
These devices must be supplied by a SELV source as defined in
the Low Voltage Directive 73/23/EEC and 93/68/EEC.