Adjusting System Time
Setting the System Time Manually: Use the date, and time commands to query the current
system date/time or to set a new system date/time.
\> date
The current date is: Tuesday, November 22, 2005
Enter the new date (mm-dd-[yy]yy): 12-23-05
\> date /T
Wednesday, November 23, 2005
\> time
The current time is: 5:27:17 PM
Enter the new time (hh:mm:ss): 16:02:00
\> time /T
4:02:04 PM
The Date/Time setting would be saved into IA26X-CE RTC. So even the system reboots the date
and time will be still the right time.
Starting and Stopping Services
After booting up, the IA26X-CE computer runs several services continuously to serve requests
from users or other programs. Notable services include telnet (“TEL0:”), console (“CON0:”),
world wide web HTTP (“HTP0:”), file transfer FTP (“FTP0:”) etc. You seldom need to care about
these services. However, you still can start up or stop a service with its associated name by using
the command “services”. For example,
Start the FTP service by
\> services start FTP0:
Stop the FTP service by
\> services stop FTP0:
The default services in IA26X-CE are listed as below:
TEL0: Telnet Service
FTP0: FTP Service
CON0: Console Service
Troubleshooting Network Connectivity
The ipconfig tool prints the TCP/IP-related configuration data of a host including the IP addresses,
gateway and DNS servers.
\> ipconfig /all
Windows IP configuration
Ethernet adapter Local Area Connection:
IP Address: 192.168.4.127
Subnet Mask: 255.255.255.0
Adapter Name: IXP425ETHNPE2
Description: IXP425ETHNPE2
Adapter Index: 2