Min. TX Output, dBm -20 -15 -5 -5
Max. TX Output, dBm -14 -6 0 0
Sensitivity, dBm -34 to -30 -36 to -32 -36 to -32 -36 to -32
Recommended Diameter
(Core/Cladding) μm
50/125 9/125 9/125 9/125
(1 dB/km, 800 MHz × km)
Power
Input Voltage 12 to 48 VDC, redundant inputs
Input Current @ 24VDC 0.25 A (EDS-305, EDS-305-M, EDS-305-S,
EDS-308)
0.35 A (EDS-308-M, EDS-308-S, EDS-308-MM,
EDS-308-SS)
Connection Removable “6-pin” Terminal Block
Overload Current
Protection
1.1 A (EDS-305, EDS-305-M, EDS-305-S,
EDS-308)
1.6 A (EDS-308-M, EDS-308-S, EDS-308-MM,
EDS-308-SS)
Reverse Polarity
Protection
Present
Mechanical
Casing IP30 protection, metal case
Dimensions
53.6 × 135 × 105 mm (W × H × D)
Weight 0.63 kg
Installation DIN-rail, Wall Mounting
Environmental
Operating Temperature 0 to 60ºC (32 to 140ºF)
-40 to 75ºC (-40 to 167ºF) for -T models
Storage Temperature -40 to 85ºC (-40 to 185ºF)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety Pending: UL60950, UL 508, CSA C22.2 No. 60950,
EN60950
Hazardous Location Pending: UL/cUL Class I, Division 2, Groups A, B,
C and D
Pending: ATEX Class I, Zone 2, EEx nC IIC
EMI FCC Part 15, CISPR (EN55022) class A
EMS EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
Shock IEC60068-2-27
Free Fall IEC60068-2-32
Vibration IEC60068-2-6
WARRANTY
5 years