MOXA EtherDevice Switch & PoE Splitter EDS-P308 & SPL-24 Hardware Installation Guide First Edition, July 2006 Moxa Networking Co., Ltd. Tel: +886-2-2910-1230 Fax: +886-2-2910-1231 www.moxa.com support@moxanet.com support@moxa.
Overview We describe two products in this manual: The MOXA EtherDevice™ EDS-P308 is an 8-port smart Ethernet switch that provides an economical solution for your Ethernet connections. The switch supports PoE (Power-over-Ethernet) on ports 1 to 4, which means that the EDS-P308 can double as a piece of power source equipment (PSE). When used in this way, the EDS-P308 can supply up to 15.4 watts of power per port, and can power IEEE 802.
environment for installing devices. PoE technology lets you eliminate the need for using power outlets to deploy Ethernet-enabled devices—such as a wireless access point (AP) or an IP camera—on a ceiling or outdoors. The devices can be placed up to 328 feet (100 m) from a PSE. Wiring Requirements WARNING Do not disconnect modules or wires unless the power supply has been switched off or the area is known to be non-hazardous. The devices may only be connected to the supply voltage shown on the type plate.
Package Checklist for EDS-P308 The MOXA EDS-P308 is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance. y y y y MOXA EtherDevice™ Switch EDS-P308 Hardware Installation Guide MOXA Product Warranty Statement Protective caps for unused ports Features of EDS-P308 High Performance Network Switching Technology y 10/100BaseT(X) (RJ45) y IEEE802.3/802.3u/802.
Power Input Voltage Input Current Connection Overload Current Protection Reverse Polarity Protection 48 VDC, redundant inputs 1.6 A (@ 48 VDC) Removable “6-pin” Terminal Block 2.5 A (@ 48 VDC) Present PoE (per port) Minimum output voltage Maximum output current Inrush current Overload detection Output current in short circuit condition Overload and short circuit time limit Turn off time Turn off voltage Maximum Output Power 500 ms 2.8V 15.
EDS-P308 Panel Layout Top Panel View 1. 2. 1 Grounding screw Terminal block for power inputs PWR1, PWR2, and relay output 3. 2 3 1 2 ON DIP switches 5. Power input PWR1 LED 6. Power input PWR2 LED 7. Fault LED 8. 10/100BaseT(X) Port 3 4 5 6 4 Heat dissipation orifices 4. 8 DIP 7 Front Panel View 2 5 6 7 9. TP port’s 100 Mbps LED 10. TP port’s 10 Mbps LED 11. Model Name 12. Screw holes for wall mounting kit 13. DIN-Rail Kit 14.
Mounting Dimensions (unit = mm) 30.00 9.00 15.10 19.80 13.10 25.40 135.00 135.00 35.00 DlN-Rail DlN-Rail Kit 105.00 Front View 3.5 Side View 6 + + 18 13.9 10 10 5 13 46.77 27.20 48.30 39.37 13 18.2 57.05 25.71 13.9 66.80 6 23.15 DlN-Rail Kit + + 7.75 30.50 7.75 53.60 Rear View Wall Mounting Kit DIN-Rail Mounting The aluminum DIN-Rail attachment plate should already be fixed to the back panel of the EDS-P308 when you take it out of the box.
Wall Mounting (optional) For some applications, you will find it convenient to mount EDS-P308 on the wall, as illustrated below. STEP 1: Remove the aluminum DIN-Rail attachment plate from the EDS-P308’s rear panel, and then attach the wall mount plates, as shown in the diagram below. top plate ⇒ bottom plate STEP 2: 6.0 mm Mounting the EDS-P308 on the wall requires 4 screws. Use the switch, with wall mount plates attached, as a guide to mark the correct locations of the 4 screws.
EDS-P308’s Redundant Power Inputs Both power inputs can be connected simultaneously to live DC power sources. If one power source fails, the other live source acts as a backup, and automatically supplies all of EDS-P308’s power needs. Wiring the Redundant Power Inputs The top two contacts and the bottom two contacts of the 6-contact terminal block connector on EDS’s top panel are used for EDS’s two DC inputs. Top and front views of one of the terminal block connectors are shown here.
EDS-P308’s DIP Switch Settings ON 1 2 DIP 3 4 5 6 7 8 ON: Enables the corresponding PORT Alarm. If the port’s link fails, the relay will form an open circuit and the fault LED will light up. Off: Disables the corresponding PORT Alarm. The relay will form a closed circuit and the Fault LED will never light up. Wiring the Alarm Contact The alarm contact consists of the two middle contacts of the terminal block on EDS’s top panel.
LED Indicators The front panel of the EDS-P308 contains several LED indicators. The function of each LED is described in the table below. LED PWR1 PWR2 FAULT 10M 100M PoE Color State On Off Power is not being supplied to power input PWR1 On Power is being supplied to power input PWR2 Off Power is not being supplied to power input PWR2 On When the corresponding PORT alarm is enabled, and the port’s link is inactive.
Package Checklist for SPL-24 The MOXA SPL-24 is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance. y MOXA PoE Splitter, SPL-24 y Hardware Installation Guide y MOXA Product Warranty Statement Features of SPL-24 High Performance Network Switching Technology y IEEE802.3af compliance y Power/data split from PoE lines using either spare-pairs or data pairs y Support for up to 12.95W at 24 VDC y Support for up to 15.
Ambient Relative Humidity 5 to 95% (non-condensing) Regulatory Approvals Safety Pending: UL60950, UL 508, CSA C22.2 No.
Mounting Dimensions (unit = mm) 74 15 32 10.5 24.87 P 74 V+ 100 76.2 100 DATA OUT OUTPUT : 24 VDC PoE IN 86.5 24.87 Side View Front View Rear View Top View DIN-Rail Mounting for SPL-24 The plastic DIN-Rail attachment plate should already be fixed to the back panel of SPL-24 when you take it out of the box. If you need to reattach the DIN-Rail attachment plate, make sure the stiff metal spring is situated towards the top, as shown in the figures below.
Grounding the SPL-24 Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the right most contact of the 3-contact terminal block to the grounding surface prior to connecting devices. ATTENTION This product is intended to be mounted to a well-grounded mounting surface, such as a metal panel. Wiring the SPL-24’s Power Outputs The two left-most contacts of the 3-contact terminal block connector on the SPL-24’s top panel are used for 24 VDC output.
MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of our products, Moxa has set up on-line support services to provide technical support, driver updates, product information, and user’s manual updates. E-mail for technical support: support@moxanet.com support@moxa.com Website for up to date product information: www.moxa.