Installation guide
- 14 -
Fast Ethernet
SFP-M SFP-S SFP-L
Wavelength 1300 nm 1310 nm 1550 nm
Max. Tx -18 dBm 0 dBm 0 dBm
Min. Tx -8 dBm -5 dBm -5 dBm
Rx Sensitivity -34 dBm -34 dBm -34 dBm
Link Budget 26 dB 29 dB 29 dB
Typical Distance 4 km
a
40 km
b
80 km
b
Saturation 0 dBm -3 dBm -3 dBm
a. 50/125 μm or 62.5/125 μm, 800 MHz * km @ 1300 nm
multi-mode fiber optic cable
b. 9/125 μm single-mode fiber optic cable
Power
Input Voltage 12/24/48 VDC,
18 to 30VAC (47 to 63 Hz), redundant inputs
Input Current (@24V) 0.92A
Connection Two removable 6-pin terminal blocks
Overload Current
Protection
Present
Reverse Polarity
Protection
Present
Mechanical
Casing IP30 protection, metal case
Dimensions (W × H × D) 87.1 × 135 × 107 mm (3.43 × 5.31 × 4.21 in)
Weight 1.41 kg
Installation DIN-Rail, Wall Mounting Kit (optional kit)
Environment
Operating Temperature 0 to 60°C (32 to 140°F), standard models
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety UL 508
Hazardous Location UL/cUL Class I, Division 2, Groups A, B, C, and D;
ATEX Class I, Zone 2, Ex nC nL IIC T4 (Pending)
EMI FCC Part 15, EN55022; class A
EMS EN55024
EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 2
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
EN61000-4-8
EN61000-4-11