User`s guide

Industrial Protocols EtherNet/IP
2-25
Bit 1: Turbo Ring,
Bit 2: Turbo Rong v2,
Bit 3: Turbo Chain,
Bit 4: MSTP
Reset Device
SINT
1: restart the device
2: reset to default
Pre-configured Tags in the Moxa AOI
The Moxa AOI supports all the CIP tags listed in the tables above. But in the AOI, we only pre-configure
logic links between selected tags and Moxa switches. To monitor the non-configured tags, PLC
programmers need to create the links manually. Otherwise, in RSLogix 5000, the value column of these
tags will display as “0”. If you experience problems creating new links, please contact Moxa technical
support for assistance.
NOTE
For pre-configured tags, Moxa has already created the logic links between the CIP tags and Moxa Ethernet
switches so RSLogix 5000 can get/set the switch information correctly.
The table below specifies all the pre-configured tags in Moxa AOI with a m ark.
Pre-Configured
Tags
Name
Identity Object (0x01)
Vendor ID
Device Type
Product Code
Revision
Status
Serial Number
Product Name
Assigned Name
Geographic Location
TCP/IP Interface Object (0xf5)
Status
Configuration Capability
Configuration Control
Physical Link Object
Interface Configuration
IP Address
Network Mask
Gateway Address
Name Server
Name Server 2
Domain Name
Host Name
Ethernet Link Object (0xf6)- by port
Interface Speed
Interface Flags
Link Status
Half/Full Duplex
Negotiation Status
Manual Setting Requires Reset
Local Hardware Fault
Physical Address
Interface Counters
In Octets
In Ucast Packets
In Nucast Packets
In Discards
In Errors
Out Octets
Out Ucast Packets
Out Nucast Packets
Out Discards
Out Errors
Media Counters
Interface Control