User`s manual
EDS-828 Series User’s Manual Featured Functions
3-43
Management VLAN ID
Setting Description Factory Default
VLAN ID
ranges from
1 to 4094
Set the management VLAN of this EDS-828. 1
Port PVID
Setting Description Factory Default
VID range from 1
to 4094
Set the port default VLAN ID for untagged devices that
connect to the port.
1
Port Fixed VLAN List (Tagged)
Setting Description Factory Default
VID range from 1
to 4094
This field will be active only when selecting the “Trunk”
port type. Set the other VLAN ID for tagged devices that
connect to the “Trunk” port. Use commas to separate
different VIDs.
None
Port Forbidden VLAN List
Setting Description Factory Default
VID range from 1
to 4094
This field will be active only when selecting the “Trunk”
port type. Set the VLAN IDs that will not be supported
by this trunk port. Use commas to separate different
VIDs.
None
VLAN Table
In this table, you can review the VLAN groups that were created, Joined Access Ports, and Trunk
Ports.
NOTE
The physical network can have a maximum of 64 VLAN settings.