EDS-828 Series User’s Manual Featured Functions
3-27
Coupling Control Port
Setting Description Factory Default
Coupling Control Port
Select any port of the EDS-828 to
be the coupling port
1-4
Configuring “Turbo Ring V2”
NOTE
When using the Dual-Ring architecture, users must configure settings for both Ring 1 and Ring 2.
In this case, the status of both rings will appear under “Current Status.”
Explanation of “Current Status” Items
Now Active
Shows which communication protocol is in use: Turbo Ring, Turbo Ring V2, RSTP, or none.
Ring 1/2—Status
Shows Healthy if the ring is operating normally, and shows Break if the ring’s backup link is
active.
Ring 1/2—Master/Slave
Indicates whether or not this EDS-828 is the Master of the Turbo Ring. (This field appears only
when selected to operate in Turbo Ring or Turbo Ring V2 mode.)
NOTE
The user does not need to set the master to use Turbo Ring. If no master is set, the Turbo Ring
protocol will assign master status to one of the EDS-828 units in the ring. The master is only used
to determine which segment serves as the backup path.