User`s manual
EDS-828 Series User’s Manual Featured Functions
3-8
Port Type
Setting Description Factory Default
Auto Allows the port to auto detect the port type of the
opposing Ethernet device and change the port
type accordingly.
MDI
MDIX
Choose the MDI or MDIX option if the opposing
Ethernet device has trouble auto-negotiating for
port type.
Auto
Network
The Network configuration allows users to modify the usual TCP/IP network parameters. An
explanation of each configuration item is given below.
Auto IP Configuration
Setting Description Factory Default
Disable Set up the EDS-828’s IP address manually.
By DHCP The EDS-828’s IP address will be assigned
automatically by the network’s DHCP server.
By BootP The EDS-828’s IP address will be assigned
automatically by the network’s BootP server.
Disable
Switch IP Address
Setting Description Factory Default
IP Address of the EDS-828 Identifies the EDS-828 on a TCP/IP network. 192.168.127.253
Switch Subnet Mask
Setting Description Factory Default
Subnet mask of the
EDS-828
Identifies the type of network to which the
EDS-828 is connected (e.g., 255.255.0.0 for a
Class B network, or 255.255.255.0 for a Class
C network).
255.255.255.0
Default Gateway
Setting Description Factory Default
Default Gateway of the
EDS-828
The IP address of the router that connects the
LAN to an outside network.
None